DL CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Delta Electronics E8 Plus-TL-US (7.716 kW)

7680 W, 240 Vac Transformerless Grid Support Utility Interactive Hybrid Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.716 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
280–480V / 480V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Delta Electronics E8 Plus-TL-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 280–480 Vdc 280V 480V MAX 480V PV DC INPUT ≤ 480V DC 7.716 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

Delta Electronics E8 Plus-TL-US Electrical and Grid-Support Specifications
ManufacturerDelta Electronics
Model Number (MPN)E8 Plus-TL-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.716 kW (7,716 W)
Nominal DC Input (Pdco)7,933 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97.5%
MPPT Operating Window280 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current20.9 A
Night Tare Loss2.72 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for E8 Plus-TL-US
Max Continuous AC Current32.1 A @ 240V
125% Continuous Duty Current40.1 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.49–10.42 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for E8 Plus-TL-US
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–24 panels8.4–10.6 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for Delta Electronics E8 Plus-TL-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Delta Electronics E8 Plus-TL-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Delta Electronics E8 Plus-TL-US

What size circuit breaker does the Delta Electronics E8 Plus-TL-US require under NEC 705.12?
At 7.716 kW continuous AC output on 240V (32.1A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Delta Electronics E8 Plus-TL-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.716 kW unit with 8.49 kW to 10.42 kW DC of solar modules without exceeding 480V cold Voc.

More Delta Electronics Inverters

SOLIVIA 7.6 NA G4 TL (7.6 kW)E8-TL-US (7.68 kW)M8-TL-US (7.68 kW)E8_BDI (7.716 kW)E8 Plus-TL-US(AC) (7.72 kW)M10-TL-US (9.62 kW)All Delta Electronics Equipment →