DL CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Delta Electronics E8-TL-US(AC) (6.494 kW)

6500 W, 240 Vac, transformerless, Bi-dierctional, Muti-mode Grid Support Utility Interactive Energy Storage Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
6.494 kW
CEC Weighted Eff.
98%
MPPT / Max DC
350–480V / 480V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Delta Electronics E8-TL-US(AC) — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 350–480 Vdc 350V 480V MAX 480V PV DC INPUT ≤ 480V DC 6.494 kW · 98% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

Delta Electronics E8-TL-US(AC) Electrical and Grid-Support Specifications
ManufacturerDelta Electronics
Model Number (MPN)E8-TL-US(AC)
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)6.494 kW (6,494 W)
Nominal DC Input (Pdco)6,623 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency98%
MPPT Operating Window350 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current16.6 A
Night Tare Loss2.1 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for E8-TL-US(AC)
Max Continuous AC Current27.1 A @ 240V
125% Continuous Duty Current33.9 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (7.14–8.77 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for E8-TL-US(AC)
Panel ClassRecommended QtyDC Array / Ratio
400W18–22 panels7.2–8.8 kW DC
440W16–20 panels7.0–8.8 kW DC
550W13–16 panels7.2–8.8 kW DC

Engineering FAQ — Delta Electronics E8-TL-US(AC)

What size circuit breaker does the Delta Electronics E8-TL-US(AC) require under NEC 705.12?
At 6.494 kW continuous AC output on 240V (27.1A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Delta Electronics E8-TL-US(AC)?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6.494 kW unit with 7.14 kW to 8.77 kW DC of solar modules without exceeding 480V cold Voc.

More Delta Electronics Inverters

E6-TL-US (5.76 kW)M6-TL-US (5.76 kW)E6_BDI (5.823 kW)SOLIVIA 6.6 NA G4 TL (6.6 kW)SOLIVIA 7.6 NA G4 TL (7.6 kW)E8-TL-US (7.68 kW)All Delta Electronics Equipment →