DL CEC-Listed · 240V ResidentialStringUL 1741-SB (3rd Ed.)

Delta Electronics M6-TL-US (5.76 kW)

6000 W, 240 Vac transformerless Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.76 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
200–480V / 480V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Delta Electronics M6-TL-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 200–480 Vdc 200V 480V MAX 480V PV DC INPUT ≤ 480V DC 5.76 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

Delta Electronics M6-TL-US Electrical and Grid-Support Specifications
ManufacturerDelta Electronics
Model Number (MPN)M6-TL-US
Inverter TopologyString Inverter
Continuous AC Power (Paco)5.76 kW (5,760 W)
Nominal DC Input (Pdco)5,916 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97.5%
MPPT Operating Window200 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current15.6 A
Night Tare Loss2.25 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for M6-TL-US
Max Continuous AC Current24 A @ 240V
125% Continuous Duty Current30.0 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.34–7.78 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for M6-TL-US
Panel ClassRecommended QtyDC Array / Ratio
400W16–19 panels6.4–7.6 kW DC
440W14–18 panels6.2–7.9 kW DC
550W12–14 panels6.6–7.7 kW DC

Compatible Solar Panels for Delta Electronics M6-TL-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Delta Electronics M6-TL-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Delta Electronics M6-TL-US

What size circuit breaker does the Delta Electronics M6-TL-US require under NEC 705.12?
At 5.76 kW continuous AC output on 240V (24A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Delta Electronics M6-TL-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.76 kW unit with 6.34 kW to 7.78 kW DC of solar modules without exceeding 480V cold Voc.

More Delta Electronics Inverters

E6-TL-US(AC) (5 kW)SOLIVIA 5.2 NA G4 TL (5.2 kW)E6-TL-US (5.76 kW)E6_BDI (5.823 kW)E8-TL-US(AC) (6.494 kW)SOLIVIA 6.6 NA G4 TL (6.6 kW)All Delta Electronics Equipment →