DL CEC-Listed · 240V ResidentialStringUL 1741-SB (3rd Ed.)

Delta Electronics M10-4-TL-US (9.674 kW)

9600 W, 240 Vac transformerless Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.674 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
280–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Delta Electronics M10-4-TL-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 280–480 Vdc 280V 480V MAX 480V PV DC INPUT ≤ 480V DC 9.674 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Delta Electronics M10-4-TL-US Electrical and Grid-Support Specifications
ManufacturerDelta Electronics
Model Number (MPN)M10-4-TL-US
Inverter TopologyString Inverter
Continuous AC Power (Paco)9.674 kW (9,674 W)
Nominal DC Input (Pdco)9,952 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97.5%
MPPT Operating Window280 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current26.2 A
Night Tare Loss1.38 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for M10-4-TL-US
Max Continuous AC Current40.3 A @ 240V
125% Continuous Duty Current50.4 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.64–13.06 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for M10-4-TL-US
Panel ClassRecommended QtyDC Array / Ratio
400W27–33 panels10.8–13.2 kW DC
440W24–30 panels10.6–13.2 kW DC
550W19–24 panels10.4–13.2 kW DC

Compatible Solar Panels for Delta Electronics M10-4-TL-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Delta Electronics M10-4-TL-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Delta Electronics M10-4-TL-US

What size circuit breaker does the Delta Electronics M10-4-TL-US require under NEC 705.12?
At 9.674 kW continuous AC output on 240V (40.3A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Delta Electronics M10-4-TL-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.674 kW unit with 10.64 kW to 13.06 kW DC of solar modules without exceeding 480V cold Voc.

More Delta Electronics Inverters

M10-TL-US (9.62 kW)E10-TL-US(AC) (9.632 kW)E10_BDI (9.674 kW)S12_BDI (11.589 kW)SOLIVIA 3.8 NA G4 TL (3.81 kW)M4-TL-US (3.84 kW)All Delta Electronics Equipment →