DL CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Delta Electronics E10-TL-US(AC) (9.632 kW)

9600 W, 240 Vac, transformerless Grid Support Utility Interactive Energy Storage Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.632 kW
CEC Weighted Eff.
98%
MPPT / Max DC
350–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Delta Electronics E10-TL-US(AC) — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 350–480 Vdc 350V 480V MAX 480V PV DC INPUT ≤ 480V DC 9.632 kW · 98% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Delta Electronics E10-TL-US(AC) Electrical and Grid-Support Specifications
ManufacturerDelta Electronics
Model Number (MPN)E10-TL-US(AC)
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.632 kW (9,632 W)
Nominal DC Input (Pdco)9,850 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency98%
MPPT Operating Window350 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current24.6 A
Night Tare Loss3.14 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for E10-TL-US(AC)
Max Continuous AC Current40.1 A @ 240V
125% Continuous Duty Current50.1 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.6–13 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for E10-TL-US(AC)
Panel ClassRecommended QtyDC Array / Ratio
400W27–33 panels10.8–13.2 kW DC
440W24–30 panels10.6–13.2 kW DC
550W19–24 panels10.4–13.2 kW DC

Engineering FAQ — Delta Electronics E10-TL-US(AC)

What size circuit breaker does the Delta Electronics E10-TL-US(AC) require under NEC 705.12?
At 9.632 kW continuous AC output on 240V (40.1A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Delta Electronics E10-TL-US(AC)?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.632 kW unit with 10.6 kW to 13 kW DC of solar modules without exceeding 480V cold Voc.

More Delta Electronics Inverters

E8_BDI (7.716 kW)E8 Plus-TL-US(AC) (7.72 kW)M10-TL-US (9.62 kW)E10_BDI (9.674 kW)M10-4-TL-US (9.674 kW)S12_BDI (11.589 kW)All Delta Electronics Equipment →