DYNAPOWER COMPANY CPS-2500 Gen5 (1353.7 kW)
1386 kW, 415Vac Grid Support Utility Interactive Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
1353.7 kW
CEC Weighted Eff.
97%
MPPT / Max DC
730–1400V / 1400V
NEC 705.12 Breaker
2400A @ 415V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | DYNAPOWER COMPANY |
|---|---|
| Model Number (MPN) | CPS-2500 Gen5 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 1353.7 kW (1,353,700 W) |
| Nominal DC Input (Pdco) | 1,397,060 W |
| Nominal AC Voltage | 415 Vac (3-Phase) |
| Listed Voltage Variants | 415V, 480V, 600V, 690V |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 730 – 1400 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1400 Vdc |
| Max DC Input Current | 1270.1 A |
| Night Tare Loss | 70.51 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | TUV Rheinland of North America |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1883.3 A @ 415V |
|---|---|
| 125% Continuous Duty Current | 2354.1 A |
| Minimum Standard Breaker | 2400 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (1489.07–1827.5 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 3723–4569 panels | 1489.2–1827.6 kW DC |
| 440W | 3384–4153 panels | 1489.0–1827.3 kW DC |
| 550W | 2707–3323 panels | 1488.8–1827.7 kW DC |
CEC-Listed 240V Equivalents to DYNAPOWER COMPANY CPS-2500 Gen5
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (1353.7 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for DYNAPOWER COMPANY CPS-2500 Gen5
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 20–24 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 20–24 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 20–23 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 21–25 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 21–25 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 16–19 per string (-10°C) | Verify Pair |
Engineering FAQ — DYNAPOWER COMPANY CPS-2500 Gen5
What size circuit breaker does the DYNAPOWER COMPANY CPS-2500 Gen5 require under NEC 705.12?
At 1353.7 kW continuous AC output on 415V (1883.3A continuous), the 125% continuous duty rule requires a minimum 2400A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the DYNAPOWER COMPANY CPS-2500 Gen5?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 1353.7 kW unit with 1489.07 kW to 1827.5 kW DC of solar modules without exceeding 1400V cold Voc.