Enphase Energy IQ7-60-2-US (0.24 kW)
240 VA, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.24 kW
CEC Weighted Eff.
97%
MPPT / Max DC
27–37V / 37V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Enphase Energy |
|---|---|
| Model Number (MPN) | IQ7-60-2-US |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.24 kW (240 W) |
| Nominal DC Input (Pdco) | 247 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 27 – 37 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 37 Vdc |
| Max DC Input Current | 7.7 A |
| Night Tare Loss | 0.03 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | UL |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 1.3 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.26–0.32 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (1.67× DC/AC) |
| 440W | 1 panel | 1:1 pairing (1.83× DC/AC) |
| 550W | 1 panel | 1:1 pairing (2.29× DC/AC) |
Compatible Solar Panels for Enphase Energy IQ7-60-2-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| REC Solar REC380AA Black | 380 W | 44.3 V | DC/AC 1.58 (1 panel/input) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO BLK ML-G10+ 380 | 380 W | 45.16 V | DC/AC 1.58 (1 panel/input) | Verify Pair |
Engineering FAQ — Enphase Energy IQ7-60-2-US
What size circuit breaker does the Enphase Energy IQ7-60-2-US require under NEC 705.12?
At 0.24 kW continuous AC output on 240V (1A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy IQ7-60-2-US?
As a 240W microinverter, it pairs 1:1 with panels rated roughly 252W to 348W STC.