Enphase Energy official logoCEC-Listed · 240V ResidentialMicroinverter

Enphase Energy S280-60-LL-x (0.27 kW)

270 W, 240 Vac, Grid Support Utility Interactive Microinverter, where x = 2, 3, 4, or 5 and may be followed by -US. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.27 kW
CEC Weighted Eff.
97%
MPPT / Max DC
27–37V / 37V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Enphase Energy S280-60-LL-x — Real Enphase rooftop microinverter hardware
Real Enphase rooftop microinverter hardwareWikimedia Commons — File:Enphase M190.jpg (CC BY-SA 3.0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 27–37 Vdc 27V 37V MAX 37V PV DC INPUT ≤ 37V DC 0.27 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Enphase Energy S280-60-LL-x Electrical and Grid-Support Specifications
ManufacturerEnphase Energy
Model Number (MPN)S280-60-LL-x
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.27 kW (270 W)
Nominal DC Input (Pdco)278 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window27 – 37 Vdc (NREL SAM Measured)
Max DC Input Voltage37 Vdc
Max DC Input Current8.7 A
Night Tare Loss0.06 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for S280-60-LL-x
Max Continuous AC Current1.1 A @ 240V
125% Continuous Duty Current1.4 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.3–0.36 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for S280-60-LL-x
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.48× DC/AC)
440W1 panel1:1 pairing (1.63× DC/AC)
550W1 panel1:1 pairing (2.04× DC/AC)

Compatible Solar Panels for Enphase Energy S280-60-LL-x

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Enphase Energy S280-60-LL-x
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Mission Solar MSX10-415HN0B {C}415 W38 VDC/AC 1.54 (1 panel/input)Verify Pair
Trina Solar TSM-415NEG9RH.25415 W34.5 VDC/AC 1.54 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415415 W38.47 VDC/AC 1.54 (1 panel/input)Verify Pair
Canadian Solar CS6.2-48TM-430H430 W35 VDC/AC 1.59 (1 panel/input)Verify Pair
Boviet Solar BVM7610M-425-H-HC-BF425 W40.7 VDC/AC 1.57 (1 panel/input)Verify Pair
REC Solar REC430AA Pure-RX430 W64.5 VDC/AC 1.59 (1 panel/input)Verify Pair

Engineering FAQ — Enphase Energy S280-60-LL-x

What size circuit breaker does the Enphase Energy S280-60-LL-x require under NEC 705.12?
At 0.27 kW continuous AC output on 240V (1.1A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy S280-60-LL-x?
As a 270W microinverter, it pairs 1:1 with panels rated roughly 284W to 392W STC.

More Enphase Energy Inverters

IQ6-60-2-US (0.23 kW)IQ7-60-2-US (0.24 kW)IQ6PLUS-ACB-LL (0.27 kW)IQ6PLUS-72-2-US (0.28 kW)IQ7PLUS-72-2-US (0.29 kW)IQ7GPLUS-72-2-US (0.298 kW)All Enphase Energy Equipment →