CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery HybridEstimated MPPT — Verify Manufacturer Datasheet
Fortress Power EdgeOn Duo 12 Lite (7.647 kW)
7.6 kW, 240 Vac Grid Support Hybrid Utility Interactive with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
7.647 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
120–500V / 600VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Fortress Power |
|---|---|
| Model Number (MPN) | EdgeOn Duo 12 Lite |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 7.647 kW (7,647 W) |
| Nominal DC Input (Pdco) | 7,925 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 240V, 208V |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 120 – 500 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design |
| Max DC Input Voltage | 600 Vdc |
| Max DC Input Current | 24.4 A |
| Night Tare Loss | 15 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | SGS |
| Built-in Revenue Meter | Yes |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 31.9 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 39.9 A |
| Minimum Standard Breaker | 40 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (8.41–10.32 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 21–26 panels | 8.4–10.4 kW DC |
| 440W | 19–23 panels | 8.4–10.1 kW DC |
| 550W | 15–19 panels | 8.3–10.4 kW DC |
Compatible Solar Panels for Fortress Power EdgeOn Duo 12 Lite
Test any of 3,007 panels with this inverter →Estimated MPPT — Verify Manufacturer DatasheetThis inverter’s MPPT window (120–500 Vdc) is a topology estimate because the CEC file did not list explicit MPPT bounds. Confirm exact startup and MPPT voltage limits on the manufacturer datasheet before finalizing string lengths.
| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 4–10 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 4–10 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 4–10 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 4–10 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 4–11 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 3–8 per string (-10°C) | Verify Pair |
Engineering FAQ — Fortress Power EdgeOn Duo 12 Lite
What size circuit breaker does the Fortress Power EdgeOn Duo 12 Lite require under NEC 705.12?
At 7.647 kW continuous AC output on 240V (31.9A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Fortress Power EdgeOn Duo 12 Lite?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.647 kW unit with 8.41 kW to 10.32 kW DC of solar modules without exceeding 600V cold Voc.