FP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery HybridEstimated MPPT — Verify Manufacturer Datasheet

Fortress Power EdgeOn Duo 9 (6.149 kW)

6 kW, 240 Vac Grid Support Hybrid Utility Interactive with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
6.149 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
120–500V / 600VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fortress Power EdgeOn Duo 9 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 120–500 Vdc 120V 500V MAX 600V PV DC INPUT ≤ 600V DC 6.149 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

Fortress Power EdgeOn Duo 9 Electrical and Grid-Support Specifications
ManufacturerFortress Power
Model Number (MPN)EdgeOn Duo 9
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)6.149 kW (6,149 W)
Nominal DC Input (Pdco)6,372 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window120 – 500 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design
Max DC Input Voltage600 Vdc
Max DC Input Current19.6 A
Night Tare Loss19.2 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for EdgeOn Duo 9
Max Continuous AC Current25.6 A @ 240V
125% Continuous Duty Current32.0 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.76–8.3 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for EdgeOn Duo 9
Panel ClassRecommended QtyDC Array / Ratio
400W17–21 panels6.8–8.4 kW DC
440W15–19 panels6.6–8.4 kW DC
550W12–15 panels6.6–8.3 kW DC

Compatible Solar Panels for Fortress Power EdgeOn Duo 9

Test any of 3,007 panels with this inverter →
Estimated MPPT — Verify Manufacturer DatasheetThis inverter’s MPPT window (120–500 Vdc) is a topology estimate because the CEC file did not list explicit MPPT bounds. Confirm exact startup and MPPT voltage limits on the manufacturer datasheet before finalizing string lengths.
Compatible Solar Panels for Fortress Power EdgeOn Duo 9
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–8 per string (-10°C)Verify Pair

Engineering FAQ — Fortress Power EdgeOn Duo 9

What size circuit breaker does the Fortress Power EdgeOn Duo 9 require under NEC 705.12?
At 6.149 kW continuous AC output on 240V (25.6A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Fortress Power EdgeOn Duo 9?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6.149 kW unit with 6.76 kW to 8.3 kW DC of solar modules without exceeding 600V cold Voc.

More Fortress Power Inverters

FP-Envy 15K (16.153 kW)Avalon HV PC50 (5.002 kW)EdgeOn Duo 7.5 (5.04 kW)Avalon HV PC76 (7.604 kW)EdgeOn Duo 12 Lite (7.647 kW)FP-ENVY-8K (7.863 kW)All Fortress Power Equipment →