FX CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

FoxESS H1-5.7-US (5.748 kW)

5.7 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.748 kW
CEC Weighted Eff.
97%
MPPT / Max DC
204–480V / 480V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
FoxESS H1-5.7-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 204–480 Vdc 204V 480V MAX 480V PV DC INPUT ≤ 480V DC 5.748 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

FoxESS H1-5.7-US Electrical and Grid-Support Specifications
ManufacturerFoxESS
Model Number (MPN)H1-5.7-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.748 kW (5,748 W)
Nominal DC Input (Pdco)5,900 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window204 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current15.5 A
Night Tare Loss27.23 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for H1-5.7-US
Max Continuous AC Current23.9 A @ 240V
125% Continuous Duty Current29.9 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.32–7.76 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for H1-5.7-US
Panel ClassRecommended QtyDC Array / Ratio
400W16–19 panels6.4–7.6 kW DC
440W14–18 panels6.2–7.9 kW DC
550W11–14 panels6.0–7.7 kW DC

Compatible Solar Panels for FoxESS H1-5.7-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for FoxESS H1-5.7-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — FoxESS H1-5.7-US

What size circuit breaker does the FoxESS H1-5.7-US require under NEC 705.12?
At 5.748 kW continuous AC output on 240V (23.9A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the FoxESS H1-5.7-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.748 kW unit with 6.32 kW to 7.76 kW DC of solar modules without exceeding 480V cold Voc.

More FoxESS Inverters

AIO-H1-5.7-US (5.687 kW)AIO-AC1-5.7-US (5.698 kW)AC1-5.7-US (5.723 kW)AC1-7.6-US (7.564 kW)AIO-H1-7.6-US (7.586 kW)AIO-AC1-7.6-US (7.593 kW)All FoxESS Equipment →