FX CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

FoxESS AIO-H1-7.6-US (7.586 kW)

7.6 kW, 240 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.586 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
271–500V / 500V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
FoxESS AIO-H1-7.6-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 271–500 Vdc 271V 500V MAX 500V PV DC INPUT ≤ 500V DC 7.586 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

FoxESS AIO-H1-7.6-US Electrical and Grid-Support Specifications
ManufacturerFoxESS
Model Number (MPN)AIO-H1-7.6-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.586 kW (7,586 W)
Nominal DC Input (Pdco)7,777 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window271 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current20.5 A
Night Tare Loss13.35 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for AIO-H1-7.6-US
Max Continuous AC Current31.6 A @ 240V
125% Continuous Duty Current39.5 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.34–10.24 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for AIO-H1-7.6-US
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for FoxESS AIO-H1-7.6-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for FoxESS AIO-H1-7.6-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–7 per string (-10°C)Verify Pair

Engineering FAQ — FoxESS AIO-H1-7.6-US

What size circuit breaker does the FoxESS AIO-H1-7.6-US require under NEC 705.12?
At 7.586 kW continuous AC output on 240V (31.6A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the FoxESS AIO-H1-7.6-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.586 kW unit with 8.34 kW to 10.24 kW DC of solar modules without exceeding 500V cold Voc.

More FoxESS Inverters

AC1-5.7-US (5.723 kW)H1-5.7-US (5.748 kW)AC1-7.6-US (7.564 kW)AIO-AC1-7.6-US (7.593 kW)H1-7.6-US (7.72 kW)AC1-9.6-US (9.419 kW)All FoxESS Equipment →