FX CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

FoxESS H1-7.6-US (7.72 kW)

7.6 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.72 kW
CEC Weighted Eff.
97%
MPPT / Max DC
271–480V / 480V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
FoxESS H1-7.6-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 271–480 Vdc 271V 480V MAX 480V PV DC INPUT ≤ 480V DC 7.72 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

FoxESS H1-7.6-US Electrical and Grid-Support Specifications
ManufacturerFoxESS
Model Number (MPN)H1-7.6-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.72 kW (7,720 W)
Nominal DC Input (Pdco)7,931 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window271 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current20.9 A
Night Tare Loss27.23 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for H1-7.6-US
Max Continuous AC Current32.2 A @ 240V
125% Continuous Duty Current40.3 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.49–10.42 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for H1-7.6-US
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–24 panels8.4–10.6 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for FoxESS H1-7.6-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for FoxESS H1-7.6-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — FoxESS H1-7.6-US

What size circuit breaker does the FoxESS H1-7.6-US require under NEC 705.12?
At 7.72 kW continuous AC output on 240V (32.2A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the FoxESS H1-7.6-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.72 kW unit with 8.49 kW to 10.42 kW DC of solar modules without exceeding 480V cold Voc.

More FoxESS Inverters

AC1-7.6-US (7.564 kW)AIO-H1-7.6-US (7.586 kW)AIO-AC1-7.6-US (7.593 kW)AC1-9.6-US (9.419 kW)AIO-H1-9.6-US (9.575 kW)AIO-AC1-9.6-US (9.585 kW)All FoxESS Equipment →