Fronius official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Fronius Primo GEN24 7.7 208-240 Plus (7.686 kW)

7.7 kW, 240 Vac Hybrid Grid Support Utility Interactive Inverter with arc detector, PLC transmitter, and meter. Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.686 kW
CEC Weighted Eff.
97%
MPPT / Max DC
260–480V / 480V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fronius Primo GEN24 7.7 208-240 Plus — Real Fronius solar inverter installation
Real Fronius solar inverter installationWikimedia Commons — File:Bregenz-Vorarlberger Kraftwerke-Inverter Test bay-Fronius Ohmpilot 9 0-3-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 260–480 Vdc 260V 480V MAX 480V PV DC INPUT ≤ 480V DC 7.686 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Fronius Primo GEN24 7.7 208-240 Plus Electrical and Grid-Support Specifications
ManufacturerFronius
Model Number (MPN)Primo GEN24 7.7 208-240 Plus
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.686 kW (7,686 W)
Nominal DC Input (Pdco)7,917 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency97%
MPPT Operating Window260 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current20.6 A
Night Tare Loss9.2 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Primo GEN24 7.7 208-240 Plus
Max Continuous AC Current32 A @ 240V
125% Continuous Duty Current40.0 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.45–10.38 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Primo GEN24 7.7 208-240 Plus
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–24 panels8.4–10.6 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for Fronius Primo GEN24 7.7 208-240 Plus

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Fronius Primo GEN24 7.7 208-240 Plus
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Fronius Primo GEN24 7.7 208-240 Plus

What size circuit breaker does the Fronius Primo GEN24 7.7 208-240 Plus require under NEC 705.12?
At 7.686 kW continuous AC output on 240V (32A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Fronius Primo GEN24 7.7 208-240 Plus?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.686 kW unit with 8.45 kW to 10.38 kW DC of solar modules without exceeding 480V cold Voc.

More Fronius Inverters