GE Renewable Energy RIU-2500-U (2507.194 kW)
2500 kVA, 550 Vac, Bi-directional, Grid Support Utility Interactive Hybrid Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
2507.194 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
800–1500V / 1500V
NEC 705.12 Breaker
3300A @ 550V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | GE Renewable Energy |
|---|---|
| Model Number (MPN) | RIU-2500-U |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 2507.194 kW (2,507,194 W) |
| Nominal DC Input (Pdco) | 2,579,160 W |
| Nominal AC Voltage | 550 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 800 – 1500 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1500 Vdc |
| Max DC Input Current | 2645.3 A |
| Night Tare Loss | 62.8 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 2631.9 A @ 550V |
|---|---|
| 125% Continuous Duty Current | 3289.9 A |
| Minimum Standard Breaker | 3300 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (2757.91–3384.71 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 6895–8462 panels | 2758.0–3384.8 kW DC |
| 440W | 6268–7693 panels | 2757.9–3384.9 kW DC |
| 550W | 5014–6154 panels | 2757.7–3384.7 kW DC |
CEC-Listed 240V Equivalents to GE Renewable Energy RIU-2500-U
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (2507.194 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for GE Renewable Energy RIU-2500-U
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 21–26 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 22–26 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 21–25 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 22–27 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 23–27 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 17–21 per string (-10°C) | Verify Pair |
Engineering FAQ — GE Renewable Energy RIU-2500-U
What size circuit breaker does the GE Renewable Energy RIU-2500-U require under NEC 705.12?
At 2507.194 kW continuous AC output on 550V (2631.9A continuous), the 125% continuous duty rule requires a minimum 3300A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the GE Renewable Energy RIU-2500-U?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 2507.194 kW unit with 2757.91 kW to 3384.71 kW DC of solar modules without exceeding 1500V cold Voc.