GoodWe GW10K-ET-20 (ET Plus+ EU) (10 kW)
10 kW, 400V 50Hz Hybrid Inverter (IEC 62109 / EN 50549 (EU/Global)). Registry source: Manufacturer IEC Datasheet (Global Reference) · CEC listing date: · Registry snapshot: .
Continuous AC Output
10 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
200–850V / 1000V
NEC 705.12 Breaker
20A @ 400V
Inverter Engineering Tools
Global / Non-US Reference: Designed for non-US 50Hz / 230V–400V grids; not UL 1741-SB listed for US interconnection.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | GoodWe |
|---|---|
| Model Number (MPN) | GW10K-ET-20 (ET Plus+ EU) |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 10 kW (10,000 W) |
| Nominal DC Input (Pdco) | 10,256 W |
| Nominal AC Voltage | 400 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 200 – 850 Vdc (Manufacturer IEC Datasheet) |
| Max DC Input Voltage | 1000 Vdc |
| Max DC Input Current | 16 A |
| Night Tare Loss | 2 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | IEC 62109 / EN 50549 (EU/Global) |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 14.4 A @ 400V |
|---|---|
| 125% Continuous Duty Current | 18.0 A |
| Minimum Standard Breaker | 20 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (11–13.5 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 28–34 panels | 11.2–13.6 kW DC |
| 440W | 25–31 panels | 11.0–13.6 kW DC |
| 550W | 20–25 panels | 11.0–13.8 kW DC |
CEC-Listed 240V Equivalents to GoodWe GW10K-ET-20 (ET Plus+ EU)
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (10 kW Hybrid Inverter) and can be added directly to your US System Kit:
Compatible Solar Panels for GoodWe GW10K-ET-20 (ET Plus+ EU)
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 6–17 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 6–17 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 6–17 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 6–18 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 6–18 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 5–14 per string (-10°C) | Verify Pair |
Engineering FAQ — GoodWe GW10K-ET-20 (ET Plus+ EU)
What size circuit breaker does the GoodWe GW10K-ET-20 (ET Plus+ EU) require under NEC 705.12?
At 10 kW continuous AC output on 400V (14.4A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the GoodWe GW10K-ET-20 (ET Plus+ EU)?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 10 kW unit with 11 kW to 13.5 kW DC of solar modules without exceeding 1000V cold Voc.