UP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Univix Power Solutions UVX10KLNA (10 kW)

10.0 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
10 kW
CEC Weighted Eff.
97%
MPPT / Max DC
280–430V / 430V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Univix Power Solutions UVX10KLNA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 280–430 Vdc 280V 430V MAX 430V PV DC INPUT ≤ 430V DC 10 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Univix Power Solutions UVX10KLNA Electrical and Grid-Support Specifications
ManufacturerUnivix Power Solutions
Model Number (MPN)UVX10KLNA
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)10 kW (10,000 W)
Nominal DC Input (Pdco)10,292 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window280 – 430 Vdc (NREL SAM Measured)
Max DC Input Voltage430 Vdc
Max DC Input Current28.6 A
Night Tare Loss33.64 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for UVX10KLNA
Max Continuous AC Current41.7 A @ 240V
125% Continuous Duty Current52.1 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (11–13.5 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for UVX10KLNA
Panel ClassRecommended QtyDC Array / Ratio
400W28–34 panels11.2–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–25 panels11.0–13.8 kW DC

Compatible Solar Panels for Univix Power Solutions UVX10KLNA

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Univix Power Solutions UVX10KLNA
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
SEG Solar SEG-560-BTC-HV560 W48.81 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-520HT4T {B}520 W48.9 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair
Trina Solar TSM-445NEG9RH.25445 W35.7 V11–11 per string (-10°C)Verify Pair
Silfab Solar SIL-540XM540 W47.95 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6.2-48TM-460H460 W36.2 V11–11 per string (-10°C)Verify Pair

Engineering FAQ — Univix Power Solutions UVX10KLNA

What size circuit breaker does the Univix Power Solutions UVX10KLNA require under NEC 705.12?
At 10 kW continuous AC output on 240V (41.7A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Univix Power Solutions UVX10KLNA?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 10 kW unit with 11 kW to 13.5 kW DC of solar modules without exceeding 430V cold Voc.

More Univix Power Solutions Inverters

UVX6KLNA (6 kW)UVX7.6KLNA (7.6 kW)UVX8KLNA (8 kW)UVX12KLNA (12 kW)UVX16LNA (16 kW)UVX5KLNA (5 kW)All Univix Power Solutions Equipment →