Growatt official logoCEC-Listed · 240V ResidentialString

Growatt 8000MTLP-US (8.061 kW)

8 kW, 240 Vac, 110-480 Vdc Grid Support Utility Interactive Inverter with boosting circuit. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
8.061 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
330–550V / 550V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Growatt 8000MTLP-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 330–550 Vdc 330V 550V MAX 550V PV DC INPUT ≤ 550V DC 8.061 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

Growatt 8000MTLP-US Electrical and Grid-Support Specifications
ManufacturerGrowatt
Model Number (MPN)8000MTLP-US
Inverter TopologyString Inverter
Continuous AC Power (Paco)8.061 kW (8,061 W)
Nominal DC Input (Pdco)8,272 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V, 277V
CEC Weighted Efficiency97.5%
MPPT Operating Window330 – 550 Vdc (NREL SAM Measured)
Max DC Input Voltage550 Vdc
Max DC Input Current17.2 A
Night Tare Loss3.5 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 8000MTLP-US
Max Continuous AC Current33.6 A @ 240V
125% Continuous Duty Current42.0 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.87–10.88 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 8000MTLP-US
Panel ClassRecommended QtyDC Array / Ratio
400W22–27 panels8.8–10.8 kW DC
440W20–25 panels8.8–11.0 kW DC
550W16–20 panels8.8–11.0 kW DC

Compatible Solar Panels for Growatt 8000MTLP-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Growatt 8000MTLP-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V9–9 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V9–9 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V9–9 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V10–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V10–10 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V7–7 per string (-10°C)Verify Pair

Engineering FAQ — Growatt 8000MTLP-US

What size circuit breaker does the Growatt 8000MTLP-US require under NEC 705.12?
At 8.061 kW continuous AC output on 240V (33.6A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Growatt 8000MTLP-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.061 kW unit with 8.87 kW to 10.88 kW DC of solar modules without exceeding 550V cold Voc.

More Growatt Inverters

7600MTLP-US (7.604 kW)MIN 7600TL-XH2 US (7.651 kW)SPH 8000TL-HU-US(B) (7.925 kW)MIN 8200TL-XH-US (8.251 kW)9000MTLP-US (9.061 kW)MIN 9000TL-XH-US (9.063 kW)All Growatt Equipment →