Growatt official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Growatt MIN 7600TL-XH2 US (7.651 kW)

7.65 kW, 240 Vac Hybrid Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.651 kW
CEC Weighted Eff.
96%
MPPT / Max DC
150–500V / 500V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Growatt MIN 7600TL-XH2 US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 150–500 Vdc 150V 500V MAX 500V PV DC INPUT ≤ 500V DC 7.651 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Growatt MIN 7600TL-XH2 US Electrical and Grid-Support Specifications
ManufacturerGrowatt
Model Number (MPN)MIN 7600TL-XH2 US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.651 kW (7,651 W)
Nominal DC Input (Pdco)7,947 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96%
MPPT Operating Window150 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current23 A
Night Tare Loss12.53 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for MIN 7600TL-XH2 US
Max Continuous AC Current31.9 A @ 240V
125% Continuous Duty Current39.9 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.42–10.33 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for MIN 7600TL-XH2 US
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for Growatt MIN 7600TL-XH2 US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Growatt MIN 7600TL-XH2 US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–7 per string (-10°C)Verify Pair

Engineering FAQ — Growatt MIN 7600TL-XH2 US

What size circuit breaker does the Growatt MIN 7600TL-XH2 US require under NEC 705.12?
At 7.651 kW continuous AC output on 240V (31.9A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Growatt MIN 7600TL-XH2 US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.651 kW unit with 8.42 kW to 10.33 kW DC of solar modules without exceeding 500V cold Voc.

More Growatt Inverters

7000MTLP-US (7.011 kW)MIN 7600TL-XH-US (7.524 kW)7600MTLP-US (7.604 kW)SPH 8000TL-HU-US(B) (7.925 kW)8000MTLP-US (8.061 kW)MIN 8200TL-XH-US (8.251 kW)All Growatt Equipment →