Growatt official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Growatt MIN 10000TL-XH2 US (10.057 kW)

10.0 kW, 240 Vac Hybrid Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
10.057 kW
CEC Weighted Eff.
96%
MPPT / Max DC
150–500V / 500V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Growatt MIN 10000TL-XH2 US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 150–500 Vdc 150V 500V MAX 500V PV DC INPUT ≤ 500V DC 10.057 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Growatt MIN 10000TL-XH2 US Electrical and Grid-Support Specifications
ManufacturerGrowatt
Model Number (MPN)MIN 10000TL-XH2 US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)10.057 kW (10,057 W)
Nominal DC Input (Pdco)10,468 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96%
MPPT Operating Window150 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current30.3 A
Night Tare Loss12.53 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for MIN 10000TL-XH2 US
Max Continuous AC Current41.9 A @ 240V
125% Continuous Duty Current52.4 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (11.06–13.58 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for MIN 10000TL-XH2 US
Panel ClassRecommended QtyDC Array / Ratio
400W28–34 panels11.2–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–25 panels11.0–13.8 kW DC

Compatible Solar Panels for Growatt MIN 10000TL-XH2 US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Growatt MIN 10000TL-XH2 US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–7 per string (-10°C)Verify Pair

Engineering FAQ — Growatt MIN 10000TL-XH2 US

What size circuit breaker does the Growatt MIN 10000TL-XH2 US require under NEC 705.12?
At 10.057 kW continuous AC output on 240V (41.9A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Growatt MIN 10000TL-XH2 US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 10.057 kW unit with 11.06 kW to 13.58 kW DC of solar modules without exceeding 500V cold Voc.

More Growatt Inverters

9000MTLP-US (9.061 kW)MIN 9000TL-XH-US (9.063 kW)SPH 10000TL-HU-US (9.925 kW)10000MTLP-US (10.058 kW)MIN 10000TL-XH-US (10.082 kW)MIN 11400TL-XH2 US (11.354 kW)All Growatt Equipment →