Growatt official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Growatt MIN 11400TL-XH2 US (11.354 kW)

9.83 kW, 208 Vac Hybrid Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.354 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
150–500V / 500V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Growatt MIN 11400TL-XH2 US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 150–500 Vdc 150V 500V MAX 500V PV DC INPUT ≤ 500V DC 11.354 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Growatt MIN 11400TL-XH2 US Electrical and Grid-Support Specifications
ManufacturerGrowatt
Model Number (MPN)MIN 11400TL-XH2 US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.354 kW (11,354 W)
Nominal DC Input (Pdco)11,835 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window150 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current34.3 A
Night Tare Loss12.53 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for MIN 11400TL-XH2 US
Max Continuous AC Current47.3 A @ 240V
125% Continuous Duty Current59.1 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.49–15.33 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for MIN 11400TL-XH2 US
Panel ClassRecommended QtyDC Array / Ratio
400W31–38 panels12.4–15.2 kW DC
440W28–35 panels12.3–15.4 kW DC
550W23–28 panels12.7–15.4 kW DC

Compatible Solar Panels for Growatt MIN 11400TL-XH2 US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Growatt MIN 11400TL-XH2 US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–7 per string (-10°C)Verify Pair

Engineering FAQ — Growatt MIN 11400TL-XH2 US

What size circuit breaker does the Growatt MIN 11400TL-XH2 US require under NEC 705.12?
At 11.354 kW continuous AC output on 240V (47.3A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Growatt MIN 11400TL-XH2 US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.354 kW unit with 12.49 kW to 15.33 kW DC of solar modules without exceeding 500V cold Voc.

More Growatt Inverters

MIN 10000TL-XH2 US (10.057 kW)10000MTLP-US (10.058 kW)MIN 10000TL-XH-US (10.082 kW)MIN 11400TL-XH-US (11.52 kW)SPH 3000TL BL-US (2.934 kW)MIN 3000TL-XH-US (3.095 kW)All Growatt Equipment →