Hongyibo New Energy Technology (Shenzhen) PCSR7K6LNA (7.765 kW)
7.6 kW, 240 Vac, Grid Support Utility Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
7.765 kW
CEC Weighted Eff.
97%
MPPT / Max DC
220–430V / 430V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Hongyibo New Energy Technology (Shenzhen) |
|---|---|
| Model Number (MPN) | PCSR7K6LNA |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 7.765 kW (7,765 W) |
| Nominal DC Input (Pdco) | 7,993 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 220 – 430 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 430 Vdc |
| Max DC Input Current | 22.2 A |
| Night Tare Loss | 30.71 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | SGS |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 32.4 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 40.5 A |
| Minimum Standard Breaker | 45 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (8.54–10.48 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 21–26 panels | 8.4–10.4 kW DC |
| 440W | 19–24 panels | 8.4–10.6 kW DC |
| 550W | 16–19 panels | 8.8–10.4 kW DC |
Compatible Solar Panels for Hongyibo New Energy Technology (Shenzhen) PCSR7K6LNA
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 6–7 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 6–7 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 6–7 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 7–7 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 7–7 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 5–6 per string (-10°C) | Verify Pair |
Engineering FAQ — Hongyibo New Energy Technology (Shenzhen) PCSR7K6LNA
What size circuit breaker does the Hongyibo New Energy Technology (Shenzhen) PCSR7K6LNA require under NEC 705.12?
At 7.765 kW continuous AC output on 240V (32.4A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Hongyibo New Energy Technology (Shenzhen) PCSR7K6LNA?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.765 kW unit with 8.54 kW to 10.48 kW DC of solar modules without exceeding 430V cold Voc.