8.0 kW, 240 Vac, Grid Support Utility Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
8.084 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
250–430V / 430V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hongyibo New Energy Technology (Shenzhen) PCSR8KLNA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–430 Vdc 250V 430V MAX 430V PV DC INPUT ≤ 430V DC 8.084 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

Hongyibo New Energy Technology (Shenzhen) PCSR8KLNA Electrical and Grid-Support Specifications
ManufacturerHongyibo New Energy Technology (Shenzhen)
Model Number (MPN)PCSR8KLNA
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)8.084 kW (8,084 W)
Nominal DC Input (Pdco)8,327 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window250 – 430 Vdc (NREL SAM Measured)
Max DC Input Voltage430 Vdc
Max DC Input Current23.1 A
Night Tare Loss17.4 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for PCSR8KLNA
Max Continuous AC Current33.7 A @ 240V
125% Continuous Duty Current42.1 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.89–10.91 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for PCSR8KLNA
Panel ClassRecommended QtyDC Array / Ratio
400W22–27 panels8.8–10.8 kW DC
440W20–25 panels8.8–11.0 kW DC
550W16–20 panels8.8–11.0 kW DC

Compatible Solar Panels for Hongyibo New Energy Technology (Shenzhen) PCSR8KLNA

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Hongyibo New Energy Technology (Shenzhen) PCSR8KLNA
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Hongyibo New Energy Technology (Shenzhen) PCSR8KLNA

What size circuit breaker does the Hongyibo New Energy Technology (Shenzhen) PCSR8KLNA require under NEC 705.12?
At 8.084 kW continuous AC output on 240V (33.7A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Hongyibo New Energy Technology (Shenzhen) PCSR8KLNA?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.084 kW unit with 8.89 kW to 10.91 kW DC of solar modules without exceeding 430V cold Voc.

More Hongyibo New Energy Technology (Shenzhen) Inverters

PCSR5KLNA (5.09 kW)PCSR6KLNA (6.117 kW)PCSR7K6LNA (7.765 kW)PCSR10KLNA (10.177 kW)All Hongyibo New Energy Technology (Shenzhen) Equipment →