HM CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Hoymiles HAS-9.6LV-USG1 (9.153 kW)

9.6 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.153 kW
CEC Weighted Eff.
94%
MPPT / Max DC
120–500V / 600V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hoymiles HAS-9.6LV-USG1 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 120–500 Vdc 120V 500V MAX 600V PV DC INPUT ≤ 600V DC 9.153 kW · 94% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

Hoymiles HAS-9.6LV-USG1 Electrical and Grid-Support Specifications
ManufacturerHoymiles
Model Number (MPN)HAS-9.6LV-USG1
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.153 kW (9,153 W)
Nominal DC Input (Pdco)9,722 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency94%
MPPT Operating Window120 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current176.8 A
Night Tare Loss6.6 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HAS-9.6LV-USG1
Max Continuous AC Current38.1 A @ 240V
125% Continuous Duty Current47.6 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.07–12.36 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HAS-9.6LV-USG1
Panel ClassRecommended QtyDC Array / Ratio
400W25–31 panels10.0–12.4 kW DC
440W23–28 panels10.1–12.3 kW DC
550W18–22 panels9.9–12.1 kW DC

Compatible Solar Panels for Hoymiles HAS-9.6LV-USG1

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Hoymiles HAS-9.6LV-USG1
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–8 per string (-10°C)Verify Pair

Engineering FAQ — Hoymiles HAS-9.6LV-USG1

What size circuit breaker does the Hoymiles HAS-9.6LV-USG1 require under NEC 705.12?
At 9.153 kW continuous AC output on 240V (38.1A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Hoymiles HAS-9.6LV-USG1?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.153 kW unit with 10.07 kW to 12.36 kW DC of solar modules without exceeding 600V cold Voc.

More Hoymiles Inverters

HYS-6.0LV-USG1 (5.995 kW)HAS-7.6LV-USG1 (7.417 kW)HYS-7.6LV-USG1 (7.708 kW)HYS-9.6LV-USG1 (9.641 kW)HYS-11.5LV-USG1 (11.575 kW)HM-300N (0.295 kW)All Hoymiles Equipment →