Hoymiles HM-300N (0.295 kW)
295 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.295 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
33–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Hoymiles |
|---|---|
| Model Number (MPN) | HM-300N |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.295 kW (295 W) |
| Nominal DC Input (Pdco) | 306 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 33 – 48 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 48 Vdc |
| Max DC Input Current | 7.7 A |
| Night Tare Loss | 0.1 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1.2 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 1.5 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.32–0.4 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (1.36× DC/AC) |
| 440W | 1 panel | 1:1 pairing (1.49× DC/AC) |
| 550W | 1 panel | 1:1 pairing (1.86× DC/AC) |
Compatible Solar Panels for Hoymiles HM-300N
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| REC Solar REC470AA Pure-RX-DC | 470 W | 65.7 V | DC/AC 1.59 (1 panel/input) | Verify Pair |
| SEG Solar SEG-465-BTE-BG | 465 W | 36.4 V | DC/AC 1.58 (1 panel/input) | Verify Pair |
| Mission Solar MSX10-460HN0B {C} | 460 W | 39.3 V | DC/AC 1.56 (1 panel/input) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | DC/AC 1.56 (1 panel/input) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445 | 445 W | 40.16 V | DC/AC 1.51 (1 panel/input) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | DC/AC 1.56 (1 panel/input) | Verify Pair |
Engineering FAQ — Hoymiles HM-300N
What size circuit breaker does the Hoymiles HM-300N require under NEC 705.12?
At 0.295 kW continuous AC output on 240V (1.2A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles HM-300N?
As a 295W microinverter, it pairs 1:1 with panels rated roughly 310W to 428W STC.