HE CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Hyperian Energy ST2-76i (7.581 kW)

7.6 kW, 240 Vac Grid Support Utility Interactive Inverter Power Conversion System. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.581 kW
CEC Weighted Eff.
97%
MPPT / Max DC
300–440V / 440V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hyperian Energy ST2-76i — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 300–440 Vdc 300V 440V MAX 440V PV DC INPUT ≤ 440V DC 7.581 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Hyperian Energy ST2-76i Electrical and Grid-Support Specifications
ManufacturerHyperian Energy
Model Number (MPN)ST2-76i
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.581 kW (7,581 W)
Nominal DC Input (Pdco)7,788 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window300 – 440 Vdc (NREL SAM Measured)
Max DC Input Voltage440 Vdc
Max DC Input Current21 A
Night Tare Loss2.5 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for ST2-76i
Max Continuous AC Current31.6 A @ 240V
125% Continuous Duty Current39.5 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.34–10.23 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for ST2-76i
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for Hyperian Energy ST2-76i

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Hyperian Energy ST2-76i
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Maxeon / SunPower SPR-MAX3-430430 W81.36 V5–5 per string (-10°C)Verify Pair

Engineering FAQ — Hyperian Energy ST2-76i

What size circuit breaker does the Hyperian Energy ST2-76i require under NEC 705.12?
At 7.581 kW continuous AC output on 240V (31.6A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Hyperian Energy ST2-76i?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.581 kW unit with 8.34 kW to 10.23 kW DC of solar modules without exceeding 440V cold Voc.

More Hyperian Energy Inverters

ST2-100i (9.956 kW)ST2-114i (11.371 kW)ST2-120i (11.968 kW)ST2-96i (9.573 kW)All Hyperian Energy Equipment →