Hyperian Energy ST2-96i (9.573 kW)
9.6 kW, 240 Vac Grid Support Utility Interactive Inverter Power Conversion System. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
9.573 kW
CEC Weighted Eff.
97%
MPPT / Max DC
300–440V / 440V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Hyperian Energy |
|---|---|
| Model Number (MPN) | ST2-96i |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 9.573 kW (9,573 W) |
| Nominal DC Input (Pdco) | 9,846 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 300 – 440 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 440 Vdc |
| Max DC Input Current | 26.6 A |
| Night Tare Loss | 2.5 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 39.9 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 49.9 A |
| Minimum Standard Breaker | 50 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (10.53–12.92 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 26–32 panels | 10.4–12.8 kW DC |
| 440W | 24–29 panels | 10.6–12.8 kW DC |
| 550W | 19–23 panels | 10.4–12.7 kW DC |
Compatible Solar Panels for Hyperian Energy ST2-96i
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Maxeon / SunPower SPR-MAX3-430 | 430 W | 81.36 V | 5–5 per string (-10°C) | Verify Pair |
Engineering FAQ — Hyperian Energy ST2-96i
What size circuit breaker does the Hyperian Energy ST2-96i require under NEC 705.12?
At 9.573 kW continuous AC output on 240V (39.9A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Hyperian Energy ST2-96i?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.573 kW unit with 10.53 kW to 12.92 kW DC of solar modules without exceeding 440V cold Voc.