HP CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

HYXI Power HYX-M600-SW-NA (0.549 kW)

0.548 kW, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.549 kW
CEC Weighted Eff.
96%
MPPT / Max DC
35–50V / 50V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
HYXI Power HYX-M600-SW-NA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 35–50 Vdc 35V 50V MAX 50V PV DC INPUT ≤ 50V DC 0.549 kW · 96% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

HYXI Power HYX-M600-SW-NA Electrical and Grid-Support Specifications
ManufacturerHYXI Power
Model Number (MPN)HYX-M600-SW-NA
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.549 kW (549 W)
Nominal DC Input (Pdco)572 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96%
MPPT Operating Window35 – 50 Vdc (NREL SAM Measured)
Max DC Input Voltage50 Vdc
Max DC Input Current13.6 A
Night Tare Loss0.2 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HYX-M600-SW-NA
Max Continuous AC Current2.3 A @ 240V
125% Continuous Duty Current2.9 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.6–0.74 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HYX-M600-SW-NA
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.73× DC/AC)
440W1 panel1:1 pairing (0.80× DC/AC)
550W1 panel1:1 pairing (1.00× DC/AC)

Compatible Solar Panels for HYXI Power HYX-M600-SW-NA

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for HYXI Power HYX-M600-SW-NA
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 1.06 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 1.06 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 1.05 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 1.02 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 1.01 (1 panel/input)Verify Pair
Trina Solar TSM-565NE19RC565 W46.3 VDC/AC 1.03 (1 panel/input)Verify Pair

Engineering FAQ — HYXI Power HYX-M600-SW-NA

What size circuit breaker does the HYXI Power HYX-M600-SW-NA require under NEC 705.12?
At 0.549 kW continuous AC output on 240V (2.3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the HYXI Power HYX-M600-SW-NA?
As a 549W microinverter, it pairs 1:1 with panels rated roughly 576W to 796W STC.

More HYXI Power Inverters

HYX-M400-S-NA (0.367 kW)HYX-M500-S-NA (0.479 kW)HYX-M600-S-NA (0.549 kW)HYX-M600-S (0.604 kW)HYX-M800-S-NA (0.723 kW)HYX-M800-S (0.8 kW)All HYXI Power Equipment →