HP CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

HYXI Power HYX-M600-SW (0.604 kW)

0.6 kW, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.604 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
35–50V / 50V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
HYXI Power HYX-M600-SW — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 35–50 Vdc 35V 50V MAX 50V PV DC INPUT ≤ 50V DC 0.604 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

HYXI Power HYX-M600-SW Electrical and Grid-Support Specifications
ManufacturerHYXI Power
Model Number (MPN)HYX-M600-SW
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.604 kW (604 W)
Nominal DC Input (Pdco)628 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window35 – 50 Vdc (NREL SAM Measured)
Max DC Input Voltage50 Vdc
Max DC Input Current15 A
Night Tare Loss0.7 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HYX-M600-SW
Max Continuous AC Current2.5 A @ 240V
125% Continuous Duty Current3.1 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.66–0.82 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HYX-M600-SW
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.66× DC/AC)
440W1 panel1:1 pairing (0.73× DC/AC)
550W1 panel1:1 pairing (0.91× DC/AC)

Compatible Solar Panels for HYXI Power HYX-M600-SW

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for HYXI Power HYX-M600-SW
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 0.96 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 0.96 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 0.95 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 0.93 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 0.92 (1 panel/input)Verify Pair
Trina Solar TSM-565NE19RC565 W46.3 VDC/AC 0.94 (1 panel/input)Verify Pair

Engineering FAQ — HYXI Power HYX-M600-SW

What size circuit breaker does the HYXI Power HYX-M600-SW require under NEC 705.12?
At 0.604 kW continuous AC output on 240V (2.5A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the HYXI Power HYX-M600-SW?
As a 604W microinverter, it pairs 1:1 with panels rated roughly 634W to 876W STC.

More HYXI Power Inverters