Ingeteam INGECON SUN 1165TL U B420 (1165 kW)
1165 kW, 420 Vac Grid Support Utility Interactive Inverter for PV and Battery Applications. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
1165 kW
CEC Weighted Eff.
98%
MPPT / Max DC
610–740V / 740V
NEC 705.12 Breaker
2100A @ 420V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Ingeteam |
|---|---|
| Model Number (MPN) | INGECON SUN 1165TL U B420 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 1165 kW (1,165,000 W) |
| Nominal DC Input (Pdco) | 1,195,080 W |
| Nominal AC Voltage | 420 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 610 – 740 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 740 Vdc |
| Max DC Input Current | 1770.5 A |
| Night Tare Loss | 80 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1601.5 A @ 420V |
|---|---|
| 125% Continuous Duty Current | 2001.9 A |
| Minimum Standard Breaker | 2100 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (1281.5–1572.75 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 3204–3932 panels | 1281.6–1572.8 kW DC |
| 440W | 2913–3574 panels | 1281.7–1572.6 kW DC |
| 550W | 2330–2860 panels | 1281.5–1573.0 kW DC |
CEC-Listed 240V Equivalents to Ingeteam INGECON SUN 1165TL U B420
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (1165 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — Ingeteam INGECON SUN 1165TL U B420
What size circuit breaker does the Ingeteam INGECON SUN 1165TL U B420 require under NEC 705.12?
At 1165 kW continuous AC output on 420V (1601.5A continuous), the 125% continuous duty rule requires a minimum 2100A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Ingeteam INGECON SUN 1165TL U B420?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 1165 kW unit with 1281.5 kW to 1572.75 kW DC of solar modules without exceeding 740V cold Voc.