JA CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Jackery GVI-HR-11K4-USG (11.084 kW)

11.4 kW, 240Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.084 kW
CEC Weighted Eff.
97%
MPPT / Max DC
245–450V / 450V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Jackery GVI-HR-11K4-USG — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 245–450 Vdc 245V 450V MAX 450V PV DC INPUT ≤ 450V DC 11.084 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Jackery GVI-HR-11K4-USG Electrical and Grid-Support Specifications
ManufacturerJackery
Model Number (MPN)GVI-HR-11K4-USG
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.084 kW (11,084 W)
Nominal DC Input (Pdco)11,377 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window245 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current29.9 A
Night Tare Loss15.36 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for GVI-HR-11K4-USG
Max Continuous AC Current46.2 A @ 240V
125% Continuous Duty Current57.8 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.19–14.96 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for GVI-HR-11K4-USG
Panel ClassRecommended QtyDC Array / Ratio
400W30–37 panels12.0–14.8 kW DC
440W28–34 panels12.3–15.0 kW DC
550W22–27 panels12.1–14.8 kW DC

Compatible Solar Panels for Jackery GVI-HR-11K4-USG

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Jackery GVI-HR-11K4-USG
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Jackery GVI-HR-11K4-USG

What size circuit breaker does the Jackery GVI-HR-11K4-USG require under NEC 705.12?
At 11.084 kW continuous AC output on 240V (46.2A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Jackery GVI-HR-11K4-USG?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.084 kW unit with 12.19 kW to 14.96 kW DC of solar modules without exceeding 450V cold Voc.

More Jackery Inverters

GVI-HR-7K6-USG (7.394 kW)All Jackery Equipment →