JA CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Jackery GVI-HR-7K6-USG (7.394 kW)

7.6 kW, 240Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.394 kW
CEC Weighted Eff.
97%
MPPT / Max DC
175–450V / 450V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Jackery GVI-HR-7K6-USG — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 175–450 Vdc 175V 450V MAX 450V PV DC INPUT ≤ 450V DC 7.394 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Jackery GVI-HR-7K6-USG Electrical and Grid-Support Specifications
ManufacturerJackery
Model Number (MPN)GVI-HR-7K6-USG
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.394 kW (7,394 W)
Nominal DC Input (Pdco)7,590 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window175 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current20 A
Night Tare Loss16.33 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for GVI-HR-7K6-USG
Max Continuous AC Current30.8 A @ 240V
125% Continuous Duty Current38.5 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.13–9.98 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for GVI-HR-7K6-USG
Panel ClassRecommended QtyDC Array / Ratio
400W20–25 panels8.0–10.0 kW DC
440W18–23 panels7.9–10.1 kW DC
550W15–18 panels8.3–9.9 kW DC

Compatible Solar Panels for Jackery GVI-HR-7K6-USG

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Jackery GVI-HR-7K6-USG
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V5–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V5–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V5–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–6 per string (-10°C)Verify Pair

Engineering FAQ — Jackery GVI-HR-7K6-USG

What size circuit breaker does the Jackery GVI-HR-7K6-USG require under NEC 705.12?
At 7.394 kW continuous AC output on 240V (30.8A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Jackery GVI-HR-7K6-USG?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.394 kW unit with 8.13 kW to 9.98 kW DC of solar modules without exceeding 450V cold Voc.

More Jackery Inverters

GVI-HR-11K4-USG (11.084 kW)All Jackery Equipment →