JingTsing Technology JTES-PCS450K-1600/740-L03C1 (459.563 kW)
450 kW, 740 Vac Grid Support Utility Interactive Energy Storage Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
459.563 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
1100–1600V / 1600V
NEC 705.12 Breaker
500A @ 740V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | JingTsing Technology |
|---|---|
| Model Number (MPN) | JTES-PCS450K-1600/740-L03C1 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 459.563 kW (459,563 W) |
| Nominal DC Input (Pdco) | 466,653 W |
| Nominal AC Voltage | 740 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 1100 – 1600 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1600 Vdc |
| Max DC Input Current | 333.3 A |
| Night Tare Loss | 3.57 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 358.6 A @ 740V |
|---|---|
| 125% Continuous Duty Current | 448.3 A |
| Minimum Standard Breaker | 500 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (505.52–620.41 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1264–1551 panels | 505.6–620.4 kW DC |
| 440W | 1149–1410 panels | 505.6–620.4 kW DC |
| 550W | 919–1128 panels | 505.4–620.4 kW DC |
CEC-Listed 240V Equivalents to JingTsing Technology JTES-PCS450K-1600/740-L03C1
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (459.563 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for JingTsing Technology JTES-PCS450K-1600/740-L03C1
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 42–42 per string (-10°C) | Verify Pair |
| REC Solar REC430AA Pure 2 | 430 W | 49 V | 30–30 per string (-10°C) | Verify Pair |
| Maxeon / SunPower SPR-MAX3-420-BLK | 420 W | 81.5 V | 18–18 per string (-10°C) | Verify Pair |
Engineering FAQ — JingTsing Technology JTES-PCS450K-1600/740-L03C1
What size circuit breaker does the JingTsing Technology JTES-PCS450K-1600/740-L03C1 require under NEC 705.12?
At 459.563 kW continuous AC output on 740V (358.6A continuous), the 125% continuous duty rule requires a minimum 500A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the JingTsing Technology JTES-PCS450K-1600/740-L03C1?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 459.563 kW unit with 505.52 kW to 620.41 kW DC of solar modules without exceeding 1600V cold Voc.