KOSTAL Solar PLENTICORE G3 S 5.5 (5.5 kW)
5.5 kW, 400V 50Hz Hybrid Inverter (VDE-AR-N 4105 / IEC 62109 (Germany/EU)). Registry source: Manufacturer IEC Datasheet (Global Reference) · CEC listing date: · Registry snapshot: .
Continuous AC Output
5.5 kW
CEC Weighted Eff.
97.4%
MPPT / Max DC
120–720V / 1000V
NEC 705.12 Breaker
15A @ 400V
Inverter Engineering Tools
Global / Non-US Reference: Designed for non-US 50Hz / 230V–400V grids; not UL 1741-SB listed for US interconnection.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | KOSTAL Solar |
|---|---|
| Model Number (MPN) | PLENTICORE G3 S 5.5 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 5.5 kW (5,500 W) |
| Nominal DC Input (Pdco) | 5,647 W |
| Nominal AC Voltage | 400 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.4% |
| MPPT Operating Window | 120 – 720 Vdc (Manufacturer IEC Datasheet) |
| Max DC Input Voltage | 1000 Vdc |
| Max DC Input Current | 17 A |
| Night Tare Loss | 2 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | VDE-AR-N 4105 / IEC 62109 (Germany/EU) |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 7.9 A @ 400V |
|---|---|
| 125% Continuous Duty Current | 9.9 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (6.05–7.43 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 15–19 panels | 6.0–7.6 kW DC |
| 440W | 14–17 panels | 6.2–7.5 kW DC |
| 550W | 11–14 panels | 6.0–7.7 kW DC |
CEC-Listed 240V Equivalents to KOSTAL Solar PLENTICORE G3 S 5.5
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (5.5 kW Hybrid Inverter) and can be added directly to your US System Kit:
Compatible Solar Panels for KOSTAL Solar PLENTICORE G3 S 5.5
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 4–17 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 4–17 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 4–17 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 4–18 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 4–18 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 3–14 per string (-10°C) | Verify Pair |
Engineering FAQ — KOSTAL Solar PLENTICORE G3 S 5.5
What size circuit breaker does the KOSTAL Solar PLENTICORE G3 S 5.5 require under NEC 705.12?
At 5.5 kW continuous AC output on 400V (7.9A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the KOSTAL Solar PLENTICORE G3 S 5.5?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.5 kW unit with 6.05 kW to 7.43 kW DC of solar modules without exceeding 1000V cold Voc.