Qcells (Hanwha) official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Qcells (Hanwha) Q.HOME+ HYB-G1-6.0 (5.57 kW)

6.0 kW, 240 Vac, single-phase, hybrid PV and battery, grid support utility interactive inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.57 kW
CEC Weighted Eff.
94%
MPPT / Max DC
240–425V / 425V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Qcells (Hanwha) Q.HOME+ HYB-G1-6.0 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 240–425 Vdc 240V 425V MAX 425V PV DC INPUT ≤ 425V DC 5.57 kW · 94% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

Qcells (Hanwha) Q.HOME+ HYB-G1-6.0 Electrical and Grid-Support Specifications
ManufacturerQcells (Hanwha)
Model Number (MPN)Q.HOME+ HYB-G1-6.0
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.57 kW (5,570 W)
Nominal DC Input (Pdco)5,867 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency94%
MPPT Operating Window240 – 425 Vdc (NREL SAM Measured)
Max DC Input Voltage425 Vdc
Max DC Input Current17.5 A
Night Tare Loss25 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Q.HOME+ HYB-G1-6.0
Max Continuous AC Current23.2 A @ 240V
125% Continuous Duty Current29.0 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.13–7.52 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Q.HOME+ HYB-G1-6.0
Panel ClassRecommended QtyDC Array / Ratio
400W15–19 panels6.0–7.6 kW DC
440W14–17 panels6.2–7.5 kW DC
550W11–14 panels6.0–7.7 kW DC

Compatible Solar Panels for Qcells (Hanwha) Q.HOME+ HYB-G1-6.0

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Qcells (Hanwha) Q.HOME+ HYB-G1-6.0
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–7 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V10–10 per string (-10°C)Verify Pair

Engineering FAQ — Qcells (Hanwha) Q.HOME+ HYB-G1-6.0

What size circuit breaker does the Qcells (Hanwha) Q.HOME+ HYB-G1-6.0 require under NEC 705.12?
At 5.57 kW continuous AC output on 240V (23.2A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Qcells (Hanwha) Q.HOME+ HYB-G1-6.0?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.57 kW unit with 6.13 kW to 7.52 kW DC of solar modules without exceeding 425V cold Voc.

More Qcells (Hanwha) Inverters

Q.VOLT A3.8SX (3.81 kW)Q.VOLT H5.0SX (5.003 kW)Q.VOLT A5.0SX (5.03 kW)Q.HOME+ AC-G1-6.0 (5.732 kW)Q.VOLT H6.0SX (6.017 kW)Q.VOLT A6.0SX (6.035 kW)All Qcells (Hanwha) Equipment →