LE CEC-Listed · 240V ResidentialMicroinverter

LeadSolar Energy LS600 (0.5 kW)

500 W, 240 Vac Grid Support Utility Interactive Micro-Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.5 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
27–45V / 45V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
LeadSolar Energy LS600 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 27–45 Vdc 27V 45V MAX 45V PV DC INPUT ≤ 45V DC 0.5 kW · 95.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

LeadSolar Energy LS600 Electrical and Grid-Support Specifications
ManufacturerLeadSolar Energy
Model Number (MPN)LS600
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.5 kW (500 W)
Nominal DC Input (Pdco)525 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency95.5%
MPPT Operating Window27 – 45 Vdc (NREL SAM Measured)
Max DC Input Voltage45 Vdc
Max DC Input Current14.6 A
Night Tare Loss0.09 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for LS600
Max Continuous AC Current2.1 A @ 240V
125% Continuous Duty Current2.6 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.55–0.68 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for LS600
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.80× DC/AC)
440W1 panel1:1 pairing (0.88× DC/AC)
550W1 panel1:1 pairing (1.10× DC/AC)

Compatible Solar Panels for LeadSolar Energy LS600

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for LeadSolar Energy LS600
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 1.16 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 1.16 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 1.15 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 1.12 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 1.11 (1 panel/input)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 VDC/AC 0.95 (1 panel/input)Verify Pair

Engineering FAQ — LeadSolar Energy LS600

What size circuit breaker does the LeadSolar Energy LS600 require under NEC 705.12?
At 0.5 kW continuous AC output on 240V (2.1A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the LeadSolar Energy LS600?
As a 500W microinverter, it pairs 1:1 with panels rated roughly 525W to 725W STC.

More LeadSolar Energy Inverters

LS600X (0.708 kW)All LeadSolar Energy Equipment →