LE CEC-Listed · 240V ResidentialMicroinverter

LeadSolar Energy LS600X (0.708 kW)

700 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.708 kW
CEC Weighted Eff.
96%
MPPT / Max DC
50–64V / 64V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
LeadSolar Energy LS600X — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 50–64 Vdc 50V 64V MAX 64V PV DC INPUT ≤ 64V DC 0.708 kW · 96% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

LeadSolar Energy LS600X Electrical and Grid-Support Specifications
ManufacturerLeadSolar Energy
Model Number (MPN)LS600X
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.708 kW (708 W)
Nominal DC Input (Pdco)734 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96%
MPPT Operating Window50 – 64 Vdc (NREL SAM Measured)
Max DC Input Voltage64 Vdc
Max DC Input Current12.9 A
Night Tare Loss0.16 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for LS600X
Max Continuous AC Current3 A @ 240V
125% Continuous Duty Current3.8 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.78–0.96 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for LS600X
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.56× DC/AC)
440W1 panel1:1 pairing (0.62× DC/AC)
550W1 panel1:1 pairing (0.78× DC/AC)

Engineering FAQ — LeadSolar Energy LS600X

What size circuit breaker does the LeadSolar Energy LS600X require under NEC 705.12?
At 0.708 kW continuous AC output on 240V (3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the LeadSolar Energy LS600X?
As a 708W microinverter, it pairs 1:1 with panels rated roughly 743W to 1027W STC.

More LeadSolar Energy Inverters

LS600 (0.5 kW)All LeadSolar Energy Equipment →