LE CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Lion Energy #50170167 Sanctuary 8K (7.898 kW)

8 kW, 240 Vac, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.898 kW
CEC Weighted Eff.
95%
MPPT / Max DC
240–425V / 425V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Lion Energy #50170167 Sanctuary 8K — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 240–425 Vdc 240V 425V MAX 425V PV DC INPUT ≤ 425V DC 7.898 kW · 95% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

Lion Energy #50170167 Sanctuary 8K Electrical and Grid-Support Specifications
ManufacturerLion Energy
Model Number (MPN)#50170167 Sanctuary 8K
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.898 kW (7,898 W)
Nominal DC Input (Pdco)8,341 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency95%
MPPT Operating Window240 – 425 Vdc (NREL SAM Measured)
Max DC Input Voltage425 Vdc
Max DC Input Current22.5 A
Night Tare Loss18.8 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for #50170167 Sanctuary 8K
Max Continuous AC Current32.9 A @ 240V
125% Continuous Duty Current41.1 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.69–10.66 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for #50170167 Sanctuary 8K
Panel ClassRecommended QtyDC Array / Ratio
400W22–27 panels8.8–10.8 kW DC
440W20–24 panels8.8–10.6 kW DC
550W16–19 panels8.8–10.4 kW DC

Compatible Solar Panels for Lion Energy #50170167 Sanctuary 8K

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Lion Energy #50170167 Sanctuary 8K
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–7 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V10–10 per string (-10°C)Verify Pair

Engineering FAQ — Lion Energy #50170167 Sanctuary 8K

What size circuit breaker does the Lion Energy #50170167 Sanctuary 8K require under NEC 705.12?
At 7.898 kW continuous AC output on 240V (32.9A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Lion Energy #50170167 Sanctuary 8K?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.898 kW unit with 8.69 kW to 10.66 kW DC of solar modules without exceeding 425V cold Voc.

More Lion Energy Inverters

Hybrid Inverter 15kW (10.177 kW)Sanctuary 3 Inverter 18kW (12.214 kW)Sanctuary 3 Inverter 24kW (16.199 kW)#50170168 (8.084 kW)Sanctuary 3 Inverter 12kW (8.181 kW)All Lion Energy Equipment →