Lion Energy Hybrid Inverter 15kW (10.177 kW)
15 kW, 240 Vac Grid Support Hybrid Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
10.177 kW
CEC Weighted Eff.
97%
MPPT / Max DC
280–430V / 430V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Lion Energy |
|---|---|
| Model Number (MPN) | Hybrid Inverter 15kW |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 10.177 kW (10,177 W) |
| Nominal DC Input (Pdco) | 10,476 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 280 – 430 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 430 Vdc |
| Max DC Input Current | 29.1 A |
| Night Tare Loss | 33.64 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | SGS |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 42.4 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 53.0 A |
| Minimum Standard Breaker | 60 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (11.19–13.74 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 28–34 panels | 11.2–13.6 kW DC |
| 440W | 25–31 panels | 11.0–13.6 kW DC |
| 550W | 20–25 panels | 11.0–13.8 kW DC |
Compatible Solar Panels for Lion Energy Hybrid Inverter 15kW
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-560-BTC-HV | 560 W | 48.81 V | 8–8 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-520HT4T {B} | 520 W | 48.9 V | 8–8 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–6 per string (-10°C) | Verify Pair |
| Trina Solar TSM-445NEG9RH.25 | 445 W | 35.7 V | 11–11 per string (-10°C) | Verify Pair |
| Silfab Solar SIL-540XM | 540 W | 47.95 V | 8–8 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 11–11 per string (-10°C) | Verify Pair |
Engineering FAQ — Lion Energy Hybrid Inverter 15kW
What size circuit breaker does the Lion Energy Hybrid Inverter 15kW require under NEC 705.12?
At 10.177 kW continuous AC output on 240V (42.4A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Lion Energy Hybrid Inverter 15kW?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 10.177 kW unit with 11.19 kW to 13.74 kW DC of solar modules without exceeding 430V cold Voc.