LS ELECTRIC LSPB-BB-0150-48-2T (151.403 kW)
151.403 kW, 480 Vac Grid Support Utility Interactive Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
151.403 kW
CEC Weighted Eff.
98%
MPPT / Max DC
250–850V / 1000VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
250A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | LS ELECTRIC |
|---|---|
| Model Number (MPN) | LSPB-BB-0150-48-2T |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 151.403 kW (151,403 W) |
| Nominal DC Input (Pdco) | 154,493 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 250 – 850 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design |
| Max DC Input Voltage | 1000 Vdc |
| Max DC Input Current | 290.2 A |
| Night Tare Loss | Not reported in CEC |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | UL |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 182.1 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 227.6 A |
| Minimum Standard Breaker | 250 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (166.54–204.39 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 416–511 panels | 166.4–204.4 kW DC |
| 440W | 379–465 panels | 166.8–204.6 kW DC |
| 550W | 303–372 panels | 166.7–204.6 kW DC |
CEC-Listed 240V Equivalents to LS ELECTRIC LSPB-BB-0150-48-2T
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (151.403 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for LS ELECTRIC LSPB-BB-0150-48-2T
Test any of 3,007 panels with this inverter →Estimated MPPT — Verify Manufacturer DatasheetThis inverter’s MPPT window (250–850 Vdc) is a topology estimate because the CEC file did not list explicit MPPT bounds. Confirm exact startup and MPPT voltage limits on the manufacturer datasheet before finalizing string lengths.
| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 7–17 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 7–17 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 7–17 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 7–18 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 7–18 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–14 per string (-10°C) | Verify Pair |
Engineering FAQ — LS ELECTRIC LSPB-BB-0150-48-2T
What size circuit breaker does the LS ELECTRIC LSPB-BB-0150-48-2T require under NEC 705.12?
At 151.403 kW continuous AC output on 480V (182.1A continuous), the 125% continuous duty rule requires a minimum 250A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the LS ELECTRIC LSPB-BB-0150-48-2T?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 151.403 kW unit with 166.54 kW to 204.39 kW DC of solar modules without exceeding 1000V cold Voc.