LS Energy Solutions PBE-6140-R61-1A0-1000 (139.449 kW)
140 kVA, 600 Vac, Bi-directional Grid Support Utility Interactive Energy Storage Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
139.449 kW
CEC Weighted Eff.
98%
MPPT / Max DC
900–1350V / 1350V
NEC 705.12 Breaker
175A @ 600V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | LS Energy Solutions |
|---|---|
| Model Number (MPN) | PBE-6140-R61-1A0-1000 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 139.449 kW (139,449 W) |
| Nominal DC Input (Pdco) | 141,900 W |
| Nominal AC Voltage | 600 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 900 – 1350 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1350 Vdc |
| Max DC Input Current | 126.1 A |
| Night Tare Loss | 1.58 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 134.2 A @ 600V |
|---|---|
| 125% Continuous Duty Current | 167.8 A |
| Minimum Standard Breaker | 175 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (153.39–188.26 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 383–471 panels | 153.2–188.4 kW DC |
| 440W | 349–428 panels | 153.6–188.3 kW DC |
| 550W | 279–342 panels | 153.4–188.1 kW DC |
CEC-Listed 240V Equivalents to LS Energy Solutions PBE-6140-R61-1A0-1000
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (139.449 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for LS Energy Solutions PBE-6140-R61-1A0-1000
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 24–24 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 34–34 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 34–35 per string (-10°C) | Verify Pair |
| REC Solar REC450AA 72 | 450 W | 53.2 V | 23–23 per string (-10°C) | Verify Pair |
| Boviet Solar BVM7609M-435-H-HC | 435 W | 39.23 V | 32–32 per string (-10°C) | Verify Pair |
| Maxeon / SunPower SPR-MAX3-435-COM | 435 W | 81.4 V | 15–15 per string (-10°C) | Verify Pair |
Engineering FAQ — LS Energy Solutions PBE-6140-R61-1A0-1000
What size circuit breaker does the LS Energy Solutions PBE-6140-R61-1A0-1000 require under NEC 705.12?
At 139.449 kW continuous AC output on 600V (134.2A continuous), the 125% continuous duty rule requires a minimum 175A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the LS Energy Solutions PBE-6140-R61-1A0-1000?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 139.449 kW unit with 153.39 kW to 188.26 kW DC of solar modules without exceeding 1350V cold Voc.