NN CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

NEP (Northern Electric & Power) BDH-8KSP-LB (7.99 kW)

8 kW, 240 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.99 kW
CEC Weighted Eff.
97%
MPPT / Max DC
220–500V / 500V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
NEP (Northern Electric & Power) BDH-8KSP-LB — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 220–500 Vdc 220V 500V MAX 500V PV DC INPUT ≤ 500V DC 7.99 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

NEP (Northern Electric & Power) BDH-8KSP-LB Electrical and Grid-Support Specifications
ManufacturerNEP (Northern Electric & Power)
Model Number (MPN)BDH-8KSP-LB
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.99 kW (7,990 W)
Nominal DC Input (Pdco)8,293 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window220 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current23 A
Night Tare Loss16.56 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for BDH-8KSP-LB
Max Continuous AC Current33.3 A @ 240V
125% Continuous Duty Current41.6 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.79–10.79 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for BDH-8KSP-LB
Panel ClassRecommended QtyDC Array / Ratio
400W22–27 panels8.8–10.8 kW DC
440W20–25 panels8.8–11.0 kW DC
550W16–20 panels8.8–11.0 kW DC

Compatible Solar Panels for NEP (Northern Electric & Power) BDH-8KSP-LB

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for NEP (Northern Electric & Power) BDH-8KSP-LB
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–7 per string (-10°C)Verify Pair

Engineering FAQ — NEP (Northern Electric & Power) BDH-8KSP-LB

What size circuit breaker does the NEP (Northern Electric & Power) BDH-8KSP-LB require under NEC 705.12?
At 7.99 kW continuous AC output on 240V (33.3A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the NEP (Northern Electric & Power) BDH-8KSP-LB?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.99 kW unit with 8.79 kW to 10.79 kW DC of solar modules without exceeding 500V cold Voc.

More NEP (Northern Electric & Power) Inverters

BDM-1200-240A (1.22 kW)BDM-1600-240A (1.533 kW)BDM-2000-240A (1.998 kW)BDH-10KSP-LB (9.991 kW)BDH-12KSP-LB (11.969 kW)BDM-300-240A (0.289 kW)All NEP (Northern Electric & Power) Equipment →