NN CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

NEP (Northern Electric & Power) BDM-1200-240A (1.22 kW)

1200 VA, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1.22 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
22–55V / 55V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
NEP (Northern Electric & Power) BDM-1200-240A — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 22–55 Vdc 22V 55V MAX 55V PV DC INPUT ≤ 55V DC 1.22 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

NEP (Northern Electric & Power) BDM-1200-240A Electrical and Grid-Support Specifications
ManufacturerNEP (Northern Electric & Power)
Model Number (MPN)BDM-1200-240A
Inverter TopologyMicroinverter
Continuous AC Power (Paco)1.22 kW (1,220 W)
Nominal DC Input (Pdco)1,266 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window22 – 55 Vdc (NREL SAM Measured)
Max DC Input Voltage55 Vdc
Max DC Input Current36.2 A
Night Tare Loss0.1 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for BDM-1200-240A
Max Continuous AC Current5.1 A @ 240V
125% Continuous Duty Current6.4 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.34–1.65 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for BDM-1200-240A
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.33× DC/AC)
440W1 panel1:1 pairing (0.36× DC/AC)
550W1 panel1:1 pairing (0.45× DC/AC)

Engineering FAQ — NEP (Northern Electric & Power) BDM-1200-240A

What size circuit breaker does the NEP (Northern Electric & Power) BDM-1200-240A require under NEC 705.12?
At 1.22 kW continuous AC output on 240V (5.1A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the NEP (Northern Electric & Power) BDM-1200-240A?
As a 1220W microinverter, it pairs 1:1 with panels rated roughly 1281W to 1769W STC.

More NEP (Northern Electric & Power) Inverters

BDM-650 (0.639 kW)BDM-800-240A (0.772 kW)BDM-1000-240A (0.934 kW)BDM-1600-240A (1.533 kW)BDM-2000-240A (1.998 kW)BDH-8KSP-LB (7.99 kW)All NEP (Northern Electric & Power) Equipment →