NEP (Northern Electric & Power) BDM-400-240A (0.398 kW)
400 VA, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.398 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
22–55V / 55V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | NEP (Northern Electric & Power) |
|---|---|
| Model Number (MPN) | BDM-400-240A |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.398 kW (398 W) |
| Nominal DC Input (Pdco) | 413 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 22 – 55 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 55 Vdc |
| Max DC Input Current | 11.8 A |
| Night Tare Loss | 0.3 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1.7 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 2.1 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.44–0.54 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (1.01× DC/AC) |
| 440W | 1 panel | 1:1 pairing (1.11× DC/AC) |
| 550W | 1 panel | 1:1 pairing (1.38× DC/AC) |
Compatible Solar Panels for NEP (Northern Electric & Power) BDM-400-240A
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | DC/AC 1.46 (1 panel/input) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | DC/AC 1.46 (1 panel/input) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | DC/AC 1.44 (1 panel/input) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | DC/AC 1.41 (1 panel/input) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | DC/AC 1.39 (1 panel/input) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | DC/AC 1.19 (1 panel/input) | Verify Pair |
Engineering FAQ — NEP (Northern Electric & Power) BDM-400-240A
What size circuit breaker does the NEP (Northern Electric & Power) BDM-400-240A require under NEC 705.12?
At 0.398 kW continuous AC output on 240V (1.7A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the NEP (Northern Electric & Power) BDM-400-240A?
As a 398W microinverter, it pairs 1:1 with panels rated roughly 418W to 577W STC.