NN CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

NEP (Northern Electric & Power) BDM-650 (0.639 kW)

639 VA, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.639 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
22–55V / 55V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
NEP (Northern Electric & Power) BDM-650 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 22–55 Vdc 22V 55V MAX 55V PV DC INPUT ≤ 55V DC 0.639 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

NEP (Northern Electric & Power) BDM-650 Electrical and Grid-Support Specifications
ManufacturerNEP (Northern Electric & Power)
Model Number (MPN)BDM-650
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.639 kW (639 W)
Nominal DC Input (Pdco)660 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window22 – 55 Vdc (NREL SAM Measured)
Max DC Input Voltage55 Vdc
Max DC Input Current18.9 A
Night Tare Loss0.12 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for BDM-650
Max Continuous AC Current2.7 A @ 240V
125% Continuous Duty Current3.4 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.7–0.86 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for BDM-650
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.63× DC/AC)
440W1 panel1:1 pairing (0.69× DC/AC)
550W1 panel1:1 pairing (0.86× DC/AC)

Compatible Solar Panels for NEP (Northern Electric & Power) BDM-650

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for NEP (Northern Electric & Power) BDM-650
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 0.91 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 0.91 (1 panel/input)Verify Pair

Engineering FAQ — NEP (Northern Electric & Power) BDM-650

What size circuit breaker does the NEP (Northern Electric & Power) BDM-650 require under NEC 705.12?
At 0.639 kW continuous AC output on 240V (2.7A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the NEP (Northern Electric & Power) BDM-650?
As a 639W microinverter, it pairs 1:1 with panels rated roughly 671W to 927W STC.

More NEP (Northern Electric & Power) Inverters

BDM-400-240A (0.398 kW)BDM-550 (0.547 kW)BDM-300X2-240A (0.576 kW)BDM-800-240A (0.772 kW)BDM-1000-240A (0.934 kW)BDM-1200-240A (1.22 kW)All NEP (Northern Electric & Power) Equipment →