PC CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Power Center D700-M2 (0.697 kW)

696 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.697 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
33–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Power Center D700-M2 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 33–48 Vdc 33V 48V MAX 48V PV DC INPUT ≤ 48V DC 0.697 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Power Center D700-M2 Electrical and Grid-Support Specifications
ManufacturerPower Center
Model Number (MPN)D700-M2
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.697 kW (697 W)
Nominal DC Input (Pdco)723 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window33 – 48 Vdc (NREL SAM Measured)
Max DC Input Voltage48 Vdc
Max DC Input Current17.2 A
Night Tare Loss0.11 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for D700-M2
Max Continuous AC Current2.9 A @ 240V
125% Continuous Duty Current3.6 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.77–0.94 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for D700-M2
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.57× DC/AC)
440W1 panel1:1 pairing (0.63× DC/AC)
550W1 panel1:1 pairing (0.79× DC/AC)

Engineering FAQ — Power Center D700-M2

What size circuit breaker does the Power Center D700-M2 require under NEC 705.12?
At 0.697 kW continuous AC output on 240V (2.9A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Power Center D700-M2?
As a 697W microinverter, it pairs 1:1 with panels rated roughly 732W to 1011W STC.

More Power Center Inverters

D350-M1 (0.349 kW)D400-M1A-240A (0.398 kW)D600-M2A-240A (0.576 kW)D800-M2A-240A (0.772 kW)D1500-M4 (1.439 kW)Essential Hybrid 5 (7.97 kW)All Power Center Equipment →