PC CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Power Center D600-M2A-240A (0.576 kW)

600 VA, 240 Vac Grid Support Utility Interactive. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.576 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
22–55V / 55V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Power Center D600-M2A-240A — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 22–55 Vdc 22V 55V MAX 55V PV DC INPUT ≤ 55V DC 0.576 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Power Center D600-M2A-240A Electrical and Grid-Support Specifications
ManufacturerPower Center
Model Number (MPN)D600-M2A-240A
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.576 kW (576 W)
Nominal DC Input (Pdco)598 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window22 – 55 Vdc (NREL SAM Measured)
Max DC Input Voltage55 Vdc
Max DC Input Current17.1 A
Night Tare Loss0.3 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for D600-M2A-240A
Max Continuous AC Current2.4 A @ 240V
125% Continuous Duty Current3.0 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.63–0.78 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for D600-M2A-240A
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.69× DC/AC)
440W1 panel1:1 pairing (0.76× DC/AC)
550W1 panel1:1 pairing (0.95× DC/AC)

Compatible Solar Panels for Power Center D600-M2A-240A

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Power Center D600-M2A-240A
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 1.01 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 1.01 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 1.00 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 0.97 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 0.96 (1 panel/input)Verify Pair
Trina Solar TSM-565NE19RC565 W46.3 VDC/AC 0.98 (1 panel/input)Verify Pair

Engineering FAQ — Power Center D600-M2A-240A

What size circuit breaker does the Power Center D600-M2A-240A require under NEC 705.12?
At 0.576 kW continuous AC output on 240V (2.4A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Power Center D600-M2A-240A?
As a 576W microinverter, it pairs 1:1 with panels rated roughly 605W to 835W STC.

More Power Center Inverters

D350-M1A-240A (0.346 kW)D350-M1 (0.349 kW)D400-M1A-240A (0.398 kW)D700-M2 (0.697 kW)D800-M2A-240A (0.772 kW)D1500-M4 (1.439 kW)All Power Center Equipment →