Power Electronics FS2800CU15 (3024.91 kW)
2800 kW, 645 Vac Grid Support Utility Interactive Inverter with combiner box. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
3024.91 kW
CEC Weighted Eff.
98%
MPPT / Max DC
913–1200V / 1200V
NEC 705.12 Breaker
3400A @ 645V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Power Electronics |
|---|---|
| Model Number (MPN) | FS2800CU15 |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 3024.91 kW (3,024,910 W) |
| Nominal DC Input (Pdco) | 3,090,990 W |
| Nominal AC Voltage | 645 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 913 – 1200 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1200 Vdc |
| Max DC Input Current | 3288.3 A |
| Night Tare Loss | 427.54 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 2707.7 A @ 645V |
|---|---|
| 125% Continuous Duty Current | 3384.6 A |
| Minimum Standard Breaker | 3400 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (3327.4–4083.63 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 8319–10209 panels | 3327.6–4083.6 kW DC |
| 440W | 7562–9281 panels | 3327.3–4083.6 kW DC |
| 550W | 6050–7425 panels | 3327.5–4083.8 kW DC |
CEC-Listed 240V Equivalents to Power Electronics FS2800CU15
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (3024.91 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — Power Electronics FS2800CU15
What size circuit breaker does the Power Electronics FS2800CU15 require under NEC 705.12?
At 3024.91 kW continuous AC output on 645V (2707.7A continuous), the 125% continuous duty rule requires a minimum 3400A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Power Electronics FS2800CU15?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3024.91 kW unit with 3327.4 kW to 4083.63 kW DC of solar modules without exceeding 1200V cold Voc.