Qcells (Hanwha) official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Qcells (Hanwha) Q.VOLT H5.0SX (5.003 kW)

5.0 kW, 240 Vac Grid support, utility-interactive hybrid inverter, with Backup Interface (BI), Q.HOME HUB 200SX. Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.003 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
230–500V / 500V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Qcells (Hanwha) Q.VOLT H5.0SX — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 230–500 Vdc 230V 500V MAX 500V PV DC INPUT ≤ 500V DC 5.003 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

Qcells (Hanwha) Q.VOLT H5.0SX Electrical and Grid-Support Specifications
ManufacturerQcells (Hanwha)
Model Number (MPN)Q.VOLT H5.0SX
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.003 kW (5,003 W)
Nominal DC Input (Pdco)5,138 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window230 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current14.1 A
Night Tare Loss1.2 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Q.VOLT H5.0SX
Max Continuous AC Current20.8 A @ 240V
125% Continuous Duty Current26.0 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.5–6.75 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Q.VOLT H5.0SX
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W13–15 panels5.7–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Compatible Solar Panels for Qcells (Hanwha) Q.VOLT H5.0SX

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Qcells (Hanwha) Q.VOLT H5.0SX
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–7 per string (-10°C)Verify Pair

Engineering FAQ — Qcells (Hanwha) Q.VOLT H5.0SX

What size circuit breaker does the Qcells (Hanwha) Q.VOLT H5.0SX require under NEC 705.12?
At 5.003 kW continuous AC output on 240V (20.8A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Qcells (Hanwha) Q.VOLT H5.0SX?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.003 kW unit with 5.5 kW to 6.75 kW DC of solar modules without exceeding 500V cold Voc.

More Qcells (Hanwha) Inverters

Q.MI.384B-P2 (0.383 kW)Q.VOLT H3.8SX (3.805 kW)Q.VOLT A3.8SX (3.81 kW)Q.VOLT A5.0SX (5.03 kW)Q.HOME+ HYB-G1-6.0 (5.57 kW)Q.HOME+ AC-G1-6.0 (5.732 kW)All Qcells (Hanwha) Equipment →