Qcells (Hanwha) official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Qcells (Hanwha) Q.HOME+ HYB-G1-8.6 (8.604 kW)

8.6 kW, 240 Vac, single-phase, hybrid PV and battery, grid support utility interactive inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
8.604 kW
CEC Weighted Eff.
96%
MPPT / Max DC
258–500V / 500V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Qcells (Hanwha) Q.HOME+ HYB-G1-8.6 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 258–500 Vdc 258V 500V MAX 500V PV DC INPUT ≤ 500V DC 8.604 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

Qcells (Hanwha) Q.HOME+ HYB-G1-8.6 Electrical and Grid-Support Specifications
ManufacturerQcells (Hanwha)
Model Number (MPN)Q.HOME+ HYB-G1-8.6
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)8.604 kW (8,604 W)
Nominal DC Input (Pdco)9,014 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96%
MPPT Operating Window258 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current23.8 A
Night Tare Loss40 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Q.HOME+ HYB-G1-8.6
Max Continuous AC Current35.9 A @ 240V
125% Continuous Duty Current44.9 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (9.46–11.62 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Q.HOME+ HYB-G1-8.6
Panel ClassRecommended QtyDC Array / Ratio
400W24–29 panels9.6–11.6 kW DC
440W22–26 panels9.7–11.4 kW DC
550W17–21 panels9.3–11.6 kW DC

Compatible Solar Panels for Qcells (Hanwha) Q.HOME+ HYB-G1-8.6

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Qcells (Hanwha) Q.HOME+ HYB-G1-8.6
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–7 per string (-10°C)Verify Pair

Engineering FAQ — Qcells (Hanwha) Q.HOME+ HYB-G1-8.6

What size circuit breaker does the Qcells (Hanwha) Q.HOME+ HYB-G1-8.6 require under NEC 705.12?
At 8.604 kW continuous AC output on 240V (35.9A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Qcells (Hanwha) Q.HOME+ HYB-G1-8.6?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.604 kW unit with 9.46 kW to 11.62 kW DC of solar modules without exceeding 500V cold Voc.

More Qcells (Hanwha) Inverters

Q.VOLT A7.6SX (7.601 kW)Q.HOME+ HYB-G1-7.6 (7.642 kW)Q.HOME+ AC-G1-7.6 (7.832 kW)Q.HOME+ AC-G1-8.6 (8.613 kW)Q.PEAK DUO BLK-G6+/AC 340 (0.29 kW)Q.MI.349B-G1 (0.349 kW)All Qcells (Hanwha) Equipment →